B-21 Infiltration of Indoor Air Pollutants to Indoor Space from The Concealed Spaces like Beam Spaces : Part.1 Equivalent Leakage Areas of the Slice Model with a Wooden Structure
-
- HAYASHI Motoya
- Miyagigakuin Women's University
-
- OSAWA Haruki
- Building Research Institute
-
- MATSUI Miyuki
- Miyagigakuin Women's University
Bibliographic Information
- Other Title
-
- B-21 天井裏等の建物内部空間からの汚染物質の室内侵入 : (第1報) 木造スライスモデルの相当隙間面積
Abstract
In order to estimate the influences of air pollutants from the concealed spaces to the indoor air quality, a slice model of Japanese common wooden structure was constructed in a laboratory. The model has two rooms on the first floor and two rooms on the second floor and also has a crawl space and two beam spaces. The equivalent leakage areas were measured using a multi fan system. The equivalent leakage areas between the concealed spaces were larger than those between the indoor spaces and the concealed spaces. The concealed spaces in the structure are connected very well.
Journal
-
- Techinical Papers of Annual Meeting the Society of Heating,Air-conditioning and Sanitary Engineers of Japan
-
Techinical Papers of Annual Meeting the Society of Heating,Air-conditioning and Sanitary Engineers of Japan 2005.2 (0), 833-836, 2005
The Society of Heating,Air-Conditioning&Sanitary Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205240127872
-
- NII Article ID
- 110009784688
-
- ISSN
- 24242179
- 18803806
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed