HPLCおよびLC/MSによる食品中のジペプチド型甘味料の同時分析

書誌事項

タイトル別名
  • Simultaneous determination of the dipeptide type sweetners in foods by HPLC and LC/MS
  • HPLC オヨビ LC/MS ニ ヨル ショクヒン チュウ ノ ジペプチドガタ カンミリョウ ノ ドウジ ブンセキ

この論文をさがす

抄録

A rapid and simple method for the simultaneous determination of the dipeptide type sweetners, those are aspartame (APM), neotame (NE) and advantame (AD), in various foods by high performance liquid chromatography (HPLC) and liquid chromatography/mass spectrometry (LC/MS) was developed. The sweetners were extracted from foods with 0.01 mol/L hydrochloric acid in ultrasonic bath, and the extract was loaded on a strata-X-C, cation-exchange and reverse-phase cartridge. The HPLC separation was performed on a Inertsil ODS-4 column (5 μm, 4 mm i.d. × 150 mm) with ultraviolet detection, using 0.01 mol/L phosphate buffer (pH3.5)-acetonitrile as a mobile phase. The LC/MS separation was performed on a InertSustain C18 column (3 μm, 2.1 mm i.d. × 50 mm) with a mobile phase of 0.01 mol/L ammonium formate-formic acid buffer (pH3.5)-methanol, and MS detection with positive ion electrospray ionization. In HPLC, the quantification limit of three sweetners was 0.001 g/kg. In LC/MS, the limit of APM was 0.005 g/kg, and that of AD and NE was 0.001 g/kg. The mean recoveries from foods fortified at the levels of 0.02 and 0.20 g/kg were 87.8-106.3% in HPLC, and 64.0-128.9% in LC/MS.