OS0604 導電率の温度特性を利用した渦電流試験による熱可塑性CFRP融着部の検査

書誌事項

タイトル別名
  • OS0604 Detection of Defects in thermoplastic CFRP Welded Zones by Eddy Current Based Approach Utilizing Temperature Characteristic of Electrical Conductivity

抄録

In recent years, thermoplastic CFRP attracts considerable attention especially in aviation and automobile industries due to weldability of thermoplastic CFRP. Ultrasonic testing (UT) is commonly adopted as a testing method for inspecting weld parts although time and cost on UT is thought to be problematic. Since eddy current testing (ET) is used for rapid and non-contact inspection on electrically conductive materials, this paper presents an eddy current based approach for detecting defects in thermoplastic CFRP welded zones. However, it is difficult for conventional ET to detect delamination which is parallel to eddy current although delamination is one of the common forms of weld defect. To detect delamination in thermoplastic CFRP welded zones, new eddy current based approach which utilizes temperature characteristic of electrical conductivity is proposed. The proposal consists of two steps. Firstly, temperature difference between intact zones and defective zones is caused by heating the one side of the weld part. Secondly, the temperature difference is detected by ET utilizing temperature dependency of electrical conductivity.