P-34 マウスピース形矯正装置における歯の移動の有限要素法シミュレーション(臨床応用,一般講演(ポスター発表),第66回日本歯科理工学会学術講演会)

書誌事項

タイトル別名
  • P-34 Finite element simulation of tooth movement produced by mousepiece orthodontic appliance

この論文をさがす

抄録

The purpose of this study was to clarify possible movement patterns achieved by a mousepiece orthodontic appliance without attachments. In cases where an upper right central incisor was translated or rotated by about 0.1 mm, orthodontic tooth movements were simulated by the finite element method. Axial rotation of the incisor was almost achieved. The incisor could move bodily in the labial direction by about half of the predicted distance. In the case of menial translation, the crown moved to the predicted position but the root apex hardly moved. Slight intrusion of the incisor was achieved, but extrusion was almost impossible.