Case Study of Reinforced Earth Wall Failure during Extreme Rainfall
-
- Shin, E. C.
- Department of Civil and Environmental Engineering, University of Incheon
-
- Cho, S. D.
- Geotechnical Engineering Lab., Korea Institute of Construction Technology
-
- Lee, K. W.
- Geotechnical Engineering Lab., Korea Institute of Construction Technology
抄録
Recently number of reinforced earth walls had problems such as cracking on the facing wall, breakage of connection pins in the modular block, differential settlement on the foundation and collapsing facing wall. This paper describes the recent application and design for both panel type and modular block type faced reinforced walls. The failure case histories of reinforced earth wall during the extreme rainfall are also presented.
International Symposium on Backwards Problem in Geotechnical Engineering and Monitoring of Geo-Construction, Green Hall, Kensetsu-Koryu-kan, 2011/07/14-15
収録刊行物
-
- Proceeding of TC302 Symposium Osaka 2011 : International Symposium on Backwards Problem in Geotechnical Engineering and Monitoring of Geo-Construction
-
Proceeding of TC302 Symposium Osaka 2011 : International Symposium on Backwards Problem in Geotechnical Engineering and Monitoring of Geo-Construction 146-153, 2011