A Shape-Directed Scaling Method for Fundus Image with Maintenance to Blood-Vessel Shapes and Color Reality
-
- Sheng Kai
- Graduate School of Systems and Information Engineering, University of Tsukuba
-
- Kameyama Keisuke
- Graduate School of Systems and Information Engineering, University of Tsukuba
-
- Toraichi Kazuo
- Graduate School of Systems and Information Engineering, University of Tsukuba
-
- Mitamura Yoshinori
- Graduate School of Engineering, Hokkaido University
-
- Katagishi Kazuki
- Graduate School of Systems and Information Engineering, University of Tsukuba
-
- Morooka Yasuo
- Graduate School of Systems and Information Engineering, University of Tsukuba
-
- Ohmiya Yasuhiro
- Graduate School of Systems and Information Engineering, University of Tsukuba
書誌事項
- タイトル別名
-
- Shape Directed Scaling Method for Fundus Image with Maintenance to Blood Vessel Shapes and Color Reality
この論文をさがす
抄録
When digitized fundus images are used in medicine, important information for clinicians' diagnosis should be maintained well after scaling. Conventional scaling methods select the interpolation kernel based on Shannon's sampling theorem which is only appropriate for band-limited signals and usually generate image with jaggy noise or blurred blood-vessel shapes that the tortuosity and diameter change of blood vessels which are important information to clinicians' diagnosis can not be maintained clearly. To solve these problems, we select the quadratic Fluency sampling function as the interpolation kernel to maintain the color reality of fundus image based on the Fluency information theory. Scaling is then realized by interpolation directed to the blood-vessel shape map of required resolution which is generated from two kinds of Fluency sampling functions. These two kinds of Fluency sampling functions are precedingly utilized to approximate shapes of blood vessels on the original fundus image according to the suggestion of specialists in fundus field. Resulting images by the proposed method show good shape maintenance of blood vessels and have a better quantitative evaluation than the generally recognized best conventional method.
収録刊行物
-
- 電気学会論文誌C(電子・情報・システム部門誌)
-
電気学会論文誌C(電子・情報・システム部門誌) 125 (9), 1399-1407, 2005
一般社団法人 電気学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679581385600
-
- NII論文ID
- 130000090062
-
- NII書誌ID
- AN10065950
-
- ISSN
- 13488155
- 03854221
-
- NDL書誌ID
- 7473289
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可