2-D PSD Diagnostic System for the Pellet Trajectory in LHD Plasmas

  • HOSHINO Mitsuyasu
    Department of Energy Engineering and Science, Nagoya University, Nagoya 464-8603, Japan
  • SAKAMOTO Ryuichi
    National Institute for Fusion Science, Toki 509-5292, Japan
  • YAMADA Hiroshi
    National Institute for Fusion Science, Toki 509-5292, Japan The Graduate University for Advanced Studies, SOKENDAI, Hayama 240-0193, Japan
  • ITOH Yasuhiko
    National Institute for Fusion Science, Toki 509-5292, Japan
  • KUMAGAI Kohki
    The Graduate University for Advanced Studies, SOKENDAI, Hayama 240-0193, Japan
  • KUMAZAWA Ryuhei
    National Institute for Fusion Science, Toki 509-5292, Japan
  • WATARI Tetsuo
    National Institute for Fusion Science, Toki 509-5292, Japan
  • the LHD Experimental Group
    National Institute for Fusion Science, Toki 509-5292, Japan

抄録

Ablation of a solid hydrogen pellet in hot plasmas of Large Helical Device (LHD) has been studied. A position sensitive detector (PSD) diagnostics has been newly installed to measure the trajectory of ablating pellets. 2-D diagnostics enables the measurement with high time (1 MHz) and spatial resolutions (80 μm). A 3-D pellet trajectory can be described by a combination of 2-D images and information of initial pellet direction and velocity. A deflection of the pellet trajectory in the neutral beam injection (NBI) heated plasmas of LHD has been observed. Means of improving the measurement accuracy of this system are also discussed.

収録刊行物

参考文献 (11)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ