0.3 μm以下の粒子に対するエアフィルタの粒子捕集性能

書誌事項

タイトル別名
  • Collection Perfomance of Air Filters for DOP Particles below 0.3μm Diameter

この論文をさがす

抄録

Collection performance of a HEPA filter and a new type filter which was recently developed for removing fine particles below 0.3μm was verified by using a laser aerosol particle counter in the particle size range from 0.12 to 0.42μm diameter in which the filter performance was not sufficiently clarified. Tested filter sheets were 14.5cm by 14.5cm in dimensions.<br>DOP particles ranging from 0.12 to 0.17μm exhibited higher penetration of HEPA filter than DOP particles from 0.27 to 0.42μm by a factor of 20 at the standard face velocity of 2.4cm/sec. The penetration of HEPA filter was 6.6×10-4 for 0.12 to 0.17μm DOP particles, and that of the new type filter was 3.1×10-6.<br>It was confirmed that overall system penetration of two HEPA filters in series could be described as the product of each stage penetration.

収録刊行物

  • 保健物理

    保健物理 17 (4), 461-467, 1982

    日本保健物理学会

被引用文献 (1)*注記

もっと見る

詳細情報 詳細情報について

  • CRID
    1390282679265756416
  • NII論文ID
    130000792629
  • NII書誌ID
    AN00228458
  • DOI
    10.5453/jhps.17.461
  • COI
    1:CAS:528:DyaL3sXlvVSku70%3D
  • ISSN
    18847560
    03676110
  • 本文言語コード
    ja
  • データソース種別
    • JaLC
    • Crossref
    • CiNii Articles
  • 抄録ライセンスフラグ
    使用不可

問題の指摘

ページトップへ