斜流ポンプの内部流れと不安定特性に及ぼす翼端羽根負荷分布の影響

書誌事項

タイトル別名
  • Effect of the Blade Loading Distribution near Blade Tip on Internal Flow and Instability Characteristics in a Mixed-Flow Pump

抄録

Instability characteristics generated with partial flow rate in a mixed-flow pump have bad influence during the pump operation. In this paper, a method to control blade loading distributions of the mixed-flow pump by a simple and easy method is shown. This method was applied to control of the blade loading distribution of the blade tip in mixed-flow pumps. Furthermore, performance and the internal flow of these pumps were examined experimentally. As a result, head and pump efficiency fell at flow rate of the best efficiency in the impeller of aft-loading, but the instability characteristics were largely improved. In addition, a reverse flow suddenly developed at the impeller inlet tip side with the decrease of the flow rate in the impeller of fore-loading, but it was shown clearly that the reverse flow did not suddenly develop in the impeller of aft-loading.

収録刊行物

被引用文献 (1)*注記

もっと見る

参考文献 (2)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘