Pulmonary function tests in excised dog lungs with small airway obstruction by beads.

  • SUGIYAMA MASAHARU
    First Department of Internal Medicine, Tohoku University School of Medicine
  • SASAKI HIDETADA
    First Department of Internal Medicine, Tohoku University School of Medicine
  • INOUE HIROSHI
    First Department of Internal Medicine, Tohoku University School of Medicine
  • NAKAMURA MASAO
    First Department of Internal Medicine, Tohoku University School of Medicine
  • SASAKI TAKAO
    First Department of Internal Medicine, Tohoku University School of Medicine
  • TAKISHIMA TAMOTSU
    First Department of Internal Medicine, Tohoku University School of Medicine

抄録

SUGIYAMA, M., SASAKI, H., INOUE, H., NAKAMURA, M., SASAKI, T. and TAKISHIMA, T. Pulmonary Function Tests in Excised Dog Lungs with Small Airway Obstruction by Beads. Tohoku J. exp. Med., 1984, 143 (2), 197-204 -About 100 beads, 2mm in diameter were wedged into the small airways of excised dog lungs. Pulmonary function tests were performed in the lungs before and after the obstruction of the small airway with beads. Of the pulmonary function tests performed, lung pressure-volume curve, lung resistance-lung volume relationship, frequency dependency of dynamic compliance, closing volume, and N2 multiwash-out curve did not show any significant alteration after small airway obstruction. Only the flow-volume curve at low lung volume showed any significant alteration. This suggests that the flow-volume curve is the most sensitive pulmonary function test in the detection of early obstructive impairment of the small airways.