- Ohtsuka Tadao
- Central Research Institute of Electric Power Industry
-
- Hasegawa Yoshikazu
- Central Research Institute of Electric Power Industry
-
- Koizumi Michio
- Central Research Institute of Electric Power Industry
-
- Ono Tatsuo
- Central Research Institute of Electric Power Industry
抄録
In the study of hydrodesulfurization of residual oil, determination of the relation between hydrogen consumption and sulfur removal is one of the most important items.<br>Khafji crude oil (sulfur content 2.78%) was hydrodesulfurized with conventional cobalt-molybdate catalyst using a flow reactor under constant hydrogen pressure at 40kg/cm2G.<br>1. Hydrogen consumption in hydrcdesulfurization was proportionally increased with increasing of sulfur removal. When sulfur removal was 50%, hydrogen consumption was approximately 40m3 per kiloliter of Khafji crude oil.<br>2. Vanadium content in oil did not decrease in mild processing, but asphaltene in oil reduced proportionally to the sulfur removal.<br>3. Reaction order of the removal of sulfur from Khafji crude oil was apparent second order.
収録刊行物
-
- Bulletin of The Japan Petroleum Institute
-
Bulletin of The Japan Petroleum Institute 9 1-6, 1967
公益社団法人 石油学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282680089873408
-
- NII論文ID
- 130003621744
-
- ISSN
- 05824656
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可