dATP content in commercial ATP samples.

この論文をさがす

抄録

dATP content in commercial ATP samples was examined by use of periodate-mediated degradation of ATP and subsequent analysis on high-performance liquid chromatography. Out of ten samples obtained from eight different distributors, six contained dATP in amounts ranging from 0.1% to 0.9%. The significance of this contamination is discussed.