After an overdosing incident at our hospital,we developed an upper limit alert system that checks doses of injection drugs for individual patients as the physician uses the computerized order entry system.Based on each patient’s converted body surface area (BSA),the upper limit for an injection is estimated through comparison with the standard upper limit in a patient with a BSA of 1.6 m2.This is done automatically in accordance with a compensation formula provided by our hospital’s safety committee.Standard upper limits for each injection are based on past records of actual injection dosages administered in our hospital and discussion with clinical departments.When a physician tries to enter an order for an injection at a dose over the upper limit,the computer system issues the alert“non-enterable”and the order cannot be placed.In the case of a regimen for which there is a legitimate reason for using a dose higher than the upper limit,the physician must explain this to the pharmacist who will then unlock the alert system using a secret password that he or she has designated.Passwords are only valid for one day.As far as we know,this is the first computerized injection dosage upper limit alert system in the world.<br>On doing a search of our database,we found that there had been 742 overdose alerts (0.47% of all injection prescriptions) during the 3 months following its introduction.Owing to the alerts,physicians altered 155 prescriptions (21.1% of all alerts).Our computerized alert system for checking injection dosages has proved to be very necessary in ensuring medication safety.
収録刊行物
-
- 医療薬学
-
医療薬学 35 (9), 615-621, 2009
一般社団法人日本医療薬学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679751297024
-
- NII論文ID
- 130004502553
-
- ISSN
- 18821499
- 1346342X
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- IRDB
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可