Study of Echocardiographic Indices in the Chronic Thromboembolic Pulmonary Hypertension Curative Effect Judgment
-
- Fujita Keiji
- Department of Clinical Laboratory, National Hospital Organization Okayama Medical Center
-
- 宮地 克維
- 国立病院機構岡山医療センター救急科 国立病院機構岡山医療センター循環器科
-
- 正木 修一
- Department of Clinical Laboratory, National Hospital Organization Okayama Medical Center
-
- 岡崎 麻利
- Department of Clinical Laboratory, National Hospital Organization Okayama Medical Center
-
- 中山 弘美
- Department of Clinical Laboratory, National Hospital Organization Okayama Medical Center
-
- 中原 弓恵
- Department of Clinical Laboratory, National Hospital Organization Okayama Medical Center
-
- 金本 優
- Department of Clinical Laboratory, National Hospital Organization Okayama Medical Center
-
- 佐藤 慎二
- 国立病院機構岡山医療センター循環器科
-
- 溝口 博喜
- 国立病院機構岡山医療センター循環器科
-
- 松原 広己
- 国立病院機構岡山医療センター循環器科 国立病院機構岡山医療センター臨床研究部
Bibliographic Information
- Other Title
-
- 慢性血栓塞栓性肺高血圧症治療効果判定における心エコー図指標の検討
Search this article
Abstract
Objectives: To clarify the echocardiographic indices for evaluating the effectiveness of balloon pulmonary angioplasty (BPA) in patients with chronic thromboembolic pulmonary hypertension (CTEPH).<br>Methods: We reviewed 28 CTEPH patients who underwent BPA from January 2010 to February 2012. Right heart catheterization and echocardiograms were performed before and after BPA. We compared the echocardiographic indices to hemodynamic data. Hemodynamic data included mean pulmonary artery pressure (mPAP) and pulmonary vascular resistance (PVR). Echocardiographic indices included the tricuspid annular plain systolic excursion (TAPSE), the tricuspid annular systolic velocity obtained by Doppler tissue imaging, the right ventricular myocardial performance index (RVIMP), the area ratio of the right ventricle to the left ventricle, the area ratio of the right atrium to the left atrium and the eccentricity index in echocardiography.<br>Results: After BPA, the mPAP and PVR were improved significantly (mPAP: before 43±11 mmHg, after 31±7 mmHg, p<0.01; PVR: before 908±367 dyne·s/cm5, after 480±174 dyne·s/cm5, p<0.01.) Although most echocardiographic indices also improved significantly, TAPSE did not improve. Multivariable analysis revealed that the eccentricity index was the best index to reflect the degree of effectiveness of BPA.<br>Conclusions: The eccentricity index was judged to be the most useful echocardiographic index to evaluate the degree of effectiveness of BPA in CTEPH patients.
Journal
-
- Japanese Journal of Medical Ultrasound Technology
-
Japanese Journal of Medical Ultrasound Technology 39 (6), 559-566, 2014
Japanese Society of Sonographers