書誌事項
- タイトル別名
-
- Attempt to Measure the Rotatory Angle in Foulage test
この論文をさがす
抄録
We devised a method to calculate the rotatory angle in the Foulage test. The middle of both thenar eminences, the pivot of the body rotation, is fixed at 5 cm forward from the center of the stabilometer. A mean deviation of the last 10 seconds period (X, Y) in the 60 seconds examination is almost the whole body's center of gravity of the end. The rotatory angle (θ) can be calculated as follows.<br> θ=tan-1(-X)/(5-Y)<br> The calculated angles (θ) of 43 vertigo patients rotated over 10 degrees were correlated very strongly with the angles measured manually with a protractor (y=0.84x+0.39 R2=0.87).
収録刊行物
-
- Equilibrium Research
-
Equilibrium Research 75 (2), 41-46, 2016
一般社団法人 日本めまい平衡医学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204949010560
-
- NII論文ID
- 130005155350
-
- ISSN
- 1882577X
- 03855716
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可