スマートフォン式光電容積脈波での血管弾性測定を目指した加速度脈波パラメータb/a比の基礎的検討 Preliminary Investigation of the b-to-a Ratio of Acceleration Plethysmogram Derived from the Smartphone Photoplethysmography

この論文にアクセスする

著者

    • 大崎 拓也 Osaki Takuya
    • 福岡工業大学 大学院工学研究科 情報システム工学専攻 Division of Information and Systems Engineering, Graduate School of Engineering, Fukuoka Institute of Technology
    • 中間 悠介 Nakama Yusuke
    • 福岡工業大学 情報工学部 情報システム工学科 Department of Information Systems Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology
    • 李 知炯 Lee Jihyoung
    • 福岡工業大学 大学院工学研究科 情報システム工学専攻|福岡工業大学 情報工学部 情報システム工学科 Division of Information and Systems Engineering, Graduate School of Engineering, Fukuoka Institute of Technology|Department of Information Systems Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology
    • 松村 健太 Matsumura Kenta
    • 北海道大学 大学院情報科学研究科 生命人間情報科学専攻 Division of Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University
    • 太田 雅規 Ohta Masanori
    • 福岡女子大学 国際文理学部 食・健康学科 Department of Food and Health Science, International College of Arts and Sciences, Fukuoka Women's University
    • 山越 健弘 Yamakoshi Takehiro
    • 福岡工業大学 大学院工学研究科 情報システム工学専攻|福岡工業大学 情報工学部 情報システム工学科 Division of Information and Systems Engineering, Graduate School of Engineering, Fukuoka Institute of Technology|Department of Information Systems Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology

抄録

<p>We compared the b (amplitude of phase II)-to-a (that of phase I) ratio of acceleration-photoplethysmogram (APPG) derived from the photoplethysmogram (PPG) device as a reference with the b/a ratio of APPG derived from smartphone (iPhone 6). In 20 participants (32.1 ± 12.5 S.D. years), simultaneous measurements of near-infrared PPG, green light PPG, and iPhone 6 PPG from the index fingers were made. The results showed that the b/a ratio of APPG derived from the green light PPG device was significantly related to b/a ratio of APPG derived from the iPhone 6 (<i>r</i> = 0.789). In addition, the mean difference in <i>Bland-Altman plots</i> between these b/a ratios was -0.012, and the limit of agreement (2 S.D.) was 0.178. The significant differences were not observed between the b/a ratios of APPGs in each wavelength. In conclusion, these findings suggest that iPhone 6 PPG might be valid measure for estimation of finger-vascular aging.</p>

収録刊行物

  • 生体医工学

    生体医工学 54Annual(27PM-Abstract), S219-S219, 2016

    一般社団法人 日本生体医工学会