高周波変圧器用ラップ接合アモルファス巻鉄心の鉄損算定
書誌事項
- タイトル別名
-
- Iron loss estimation of amorphous wound core with lap-joint for high-frequency transformers
抄録
<p> To investigate loss-reduction schemes for the lap-joint amorphous wound core of the high-frequency transformer (HFT) of the isolated DC-DC converter used in the HVDC grid system, we tested the frequency, f performance of iron loss, Pi, of two types of amorphous HFTs up to 6 kHz. Their cores had the same specifications except for the mean magnetic path length. From the Pi-difference between them, the loss density in the laminated part of the amorphous foils, Wu, and the net loss induced by the crossing flux at the lap-joint part, PL, could be estimated separately. By parameter-fitting with the iron loss equation, it was revealed that Wu had an eddy-current loss coefficient that was close to that of the previously studied results for as-cast amorphous foils, and PL increased in proportion to square of f. We also discuss the impact of the lap-joint structure on the total loss of HFT in an electromagnetic analysis.</p>