Newly developed data-matching methodology for oral implant surgery allowing the automatic deletion of metal artifacts in 3D-CT images using new reference markers: A case report
-
- Shimizu Hiroaki
- Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences,Okayama
-
- Arakawa Hikaru
- Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences,Okayama
-
- Mino Takuya
- Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences,Okayama
-
- Kurosaki Yoko
- Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences,Okayama
-
- Tokumoto Kana
- Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences,Okayama
-
- Kuboki Takuo
- Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences,Okayama
この論文をさがす
抄録
Patients: The patient was a 55-year-old woman with left upper molar free-end edentulism and 9 full cast metal crowns in her mouth. Three three-dimensional (3D) images were superimposed: a computed tomography (CT) image with the patient wearing the CT-matching template (CTMT) with six glass ceramic markers, which hardly generate any artifacts, on the template surface, and oral plaster model surfaces with and without CTMTs. Metal artifacts were automatically removed by a Boolean operation identifying unrealistic images outside the oral plaster model surface. After the preoperative simulation, fully guided oral implant surgery was performed. Two implant bodies were placed in the left upper edentulism. The placement errors calculated by comparing the preoperative simulation and actual implant placement were then assessed by a software program using the 3D-CT bone morphology as a reference. The 3D deviations between the preoperative simulation and actual placement at the entry of the implant body were a maximum 0.48 mm and minimum 0.26 mm. Those at the tip of the implant body were a maximum 0.56 mm and a minimum 0.25 mm.<br> Discussion: In this case, the maximum 3D deviations at the entry and tip section were less than in previous studies using double CT.<br> Conclusions: Accurate image fusion utilizing CTMT with new reference markers was possible for a patient with many metal restorations. Using a surgical guide manufactured by the new matching methodology (modified single CT scan method), implant placement deviation can be minimized in patients with many metal restorations.
収録刊行物
-
- Journal of Prosthodontic Research
-
Journal of Prosthodontic Research 65 (1), 125-129, 2021
公益社団法人 日本補綴歯科学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390005667265140480
-
- NII論文ID
- 130007990283
-
- NII書誌ID
- AA12395171
-
- ISSN
- 18839207
- 22124632
- 18831958
-
- PubMed
- 32938868
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- IRDB
- Crossref
- PubMed
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可