牛乳分析用赤外分光分析器を用いた牛乳リポリシスの簡易判定法
書誌事項
- タイトル別名
-
- Convenient Detection of Lipolized Milk by Infrared Milk Analyzer
- ギュウニュウ ブンセキヨウ セキガイ ブンコウ ブンセキ キ オ モチイタ ギュウニュウ リポリシス ノ カンイ ハンテイホウ
この論文をさがす
抄録
We developed a noble method for detection of lipolyzed milk by using infrared milk analyzer (Milko Scan 134A/B, which can determine the content of fat by two wavelength. The contents measured on 5.7 μm and 3.51 μm are named as Fat A and Fat B, respectively). The method is based on the observations as follows. 1) Treatment of milk with lipase decreased Fat A and slightly increased Fat B. 2) This change was due to the change of spectrogram by lipolysis of milk. 3) The value of Fat B/Fat A on lipolysis-induced milk positively correlated with the content of free fatty acid. 4) The value of Fat B/Fat A on individual milk collected from farms also positively correlated with the content of free fatty acid.
牛乳分析用赤外分光分析器(ミルコスキヤン134A/B)においては,二波長による脂肪含量の測定が可能である(5.7/μmでの測定値を Fat A,3.5μmでの測定値をFat B と称する)。牛乳に人為的リポリシスを誘導することにより, Fat Aは著しく低下し, Fat B は若干上昇した。この変化は,リポリシスにより Fat A, Fat B の各測定波長付近の赤外スペクトルが変化することが原因であった。人為的リポリシスを誘導した牛乳においては, Fat B/ Fat A 値と遊離脂肪酸量の間に正の相関が認められ、また,人為的リポリシスを話導しない個体乳においても同様の相関が認められた。以上の結果より, 我々は, Fat B/Fat A 値による牛乳リポリシスの簡易判定法を確立した。