書誌事項
- タイトル別名
-
- INVESTIGATION OF SEISMIC CAPACITY GRADE BETWEEN GENERAL DIAGNOSIS AND DETAILED DIAGNOSIS OF TYPE1
- イッパン シンダンホウ ヒョウテン ト セイミツ シンダンホウ 1 ヒョウテン ノ ヒカク ケントウ
この論文をさがす
抄録
For the seismic diagnosis of the existing wooden house, usually the general diagnosis or the detailed diagnosis of type 1 is used. The general diagnosis is the screening that the seismic retrofit are needed or not, and it’s calculation is very simple. Therefore, the seismic capacity grade of the general diagnosis should be controlled to become smaller than the one of the detailed diagnosis of type 1. However, as a matter of fact, it often happens that the seismic capacity grades of the general diagnosis becomes larger than the one of the detailed diagnosis of type 1. The reason of this phenomenon can be considered that the strength of walls except earthquake resistant walls are often evaluated larger than that of actual strength by the general diagnosis. <br>Therefore, we propose modified calculation coefficients of the general diagnosis on the strength of wall except earthquake resistant wall based on the seismic diagnosis of the existing wooden houses. Adopting this method, we can get more accurate seismic capacity grade of the general diagnosis.
収録刊行物
-
- 日本建築学会技術報告集
-
日本建築学会技術報告集 18 (40), 947-952, 2012
一般社団法人 日本建築学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680146619520
-
- NII論文ID
- 130004932718
-
- NII書誌ID
- AN10531441
-
- ISSN
- 18818188
- 13419463
-
- NDL書誌ID
- 024038061
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可