Favorable Vessel Healing After Nobori Biolimus A9-Eluting Stent Implantation : 6- and 12-Month Follow-up by Optical Coherence Tomography
-
- Konishi Akihide
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Shinke Toshiro
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Otake Hiromasa
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Takaya Tomofumi
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Nakagawa Masayuki
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Inoue Takumi
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Hariki Hirotoshi
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Osue Tsuyoshi
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Taniguchi Yu
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Iwasaki Masamichi
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Nishio Ryo
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Hiranuma Noritoshi
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Kinutani Hiroto
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Kuroda Masaru
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Takahashi Hachidai
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Terashita Daisuke
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Shite Junya
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
-
- Hirata Ken-ichi
- Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
書誌事項
- タイトル別名
-
- Favorable Vessel Healing After Nobori Biolimus A9-Eluting Stent Implantation
- – 6- and 12-Month Follow-up by Optical Coherence Tomography –
この論文をさがす
抄録
Background:Nobori is a novel biolimus A9-eluting stent (BES) coated with a biodegradable polymer only on the abluminal side, which degrades over 6–9 months post-stent deployment. The course of vessel reaction after deployment at these time points remains unclear.Methods and Results:We serially evaluated 28 BES implanted in de novo coronary lesions of 23 patients using optical coherence tomography (OCT) at 6 and 12 months post-stenting. Standard OCT variables, the percentage of stent with peri-strut low-intensity area (PLIA, a region around stent struts homogenously showing lesser intensity than the surrounding tissue, suggesting fibrin deposition or impaired neointima maturation) and that with in-stent thrombi were evaluated. There was a significant, but small increase in neointimal thickness (72±23 to 82±25 µm, P=0.006) from the 6- to the 12-month follow-up, without a significant decrease in minimum lumen area (P=0.30). The incidences of uncovered and malapposed struts were low at 6 months and reduced further at 12 months (3.96±3.97% to 1.51±1.63%, P=0.001, and 0.50±1.84% to 0.06±0.24%, P=0.20, respectively). The frequency of stent with PLIA decreased during the follow-up (57% to 32%, P=0.05) and that with in-stent thrombi also numerically decreased (7% to 0%, P=0.24).Conclusions:Neointimal hyperplasia was persistently suppressed following BES implantation up to 12 months. Simultaneously, favorable vessel healing was achieved at 6 months without a delaying adverse reaction for up to 12 months. (Circ J 2014; 78: 1882–1890)
収録刊行物
-
- Circulation Journal
-
Circulation Journal 78 (8), 1882-1890, 2014
一般社団法人 日本循環器学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001205107582208
-
- NII論文ID
- 40020130189
- 130004427944
-
- NII書誌ID
- AA11591968
-
- COI
- 1:STN:280:DC%2BC2cfgtlCltg%3D%3D
-
- ISSN
- 13474820
- 13469843
-
- NDL書誌ID
- 025599266
-
- PubMed
- 24909891
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- PubMed
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可