Performance Evaluation and Usage Guidelines for Iodine Adsorption Cartridges for Gas Respirators under Similar Environmental Conditions to those of the Accident at the Fukushima Daiichi Nuclear Power Station

この論文をさがす

抄録

A quantitative assessment was carried out to evaluate the performance of iodine adsorption cartridges attached to gas and powered air-purifying respirators, under radioactive iodine concentrations, temperatures, and humidity conditions simulating the post-earthquake conditions at Fukushima Daiichi Nuclear Power Station. The test was conducted at the temperature of 30℃, the radioactive iodine concentration (radioactive methyl iodine concentration) and humidity conditions were varied, radioactive methyl iodine was directly aerated into the adsorption cartridges for a maximum of 10 hours, and the radioactive iodine removal performance of the adsorption cartridges was assessed. Some adsorption cartridges demonstrated a radioactive iodine removal performance of 10 hours or more, while the performance of others decreased with higher relative humidity. Based on the results of these performance assessments, respirator-wearing guidelines at Fukushima Daiichi Nuclear Power Station were established.

収録刊行物

  • 保健物理

    保健物理 51 (4), 227-237, 2016

    日本保健物理学会

被引用文献 (1)*注記

もっと見る

参考文献 (2)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘