Assessment of indoor air quality based on human olfactory sensation 人間の嗅覚に基づく室内空気質の評価に関する研究

この論文をさがす

著者

    • 岩下, 剛 イワシタ, ゴウ

書誌事項

タイトル

Assessment of indoor air quality based on human olfactory sensation

タイトル別名

人間の嗅覚に基づく室内空気質の評価に関する研究

著者名

岩下, 剛

著者別名

イワシタ, ゴウ

学位授与大学

早稲田大学

取得学位

工学博士

学位授与番号

甲第907号

学位授与年月日

1992-03-15

注記・抄録

博士論文

目次

  1. CONTENTS / p1 (0003.jp2)
  2. Chapter1 / p1 (0005.jp2)
  3. General Introduction / p1 (0005.jp2)
  4. 1-1 Purpose of research / p3 (0006.jp2)
  5. 1-2 Outline of research / p5 (0007.jp2)
  6. 1-3 Sick building syndrome / p7 (0008.jp2)
  7. 1-4 Air quality assessment based on human olfactory sensation / p9 (0009.jp2)
  8. 1-5 Fanger's olf and decipol / p12 (0011.jp2)
  9. Chapter2 / p19 (0014.jp2)
  10. Ventilation Requirements for the Control of Human Bioeffluents / p19 (0014.jp2)
  11. 2-1 Introduction / p21 (0015.jp2)
  12. 2-2 Experimental method / p22 (0016.jp2)
  13. 2-3 Results / p32 (0021.jp2)
  14. 2-4 Discussion / p43 (0026.jp2)
  15. 2-5 Conclusions / p45 (0027.jp2)
  16. Chapter3 / p47 (0028.jp2)
  17. Experiments with Naive Panel on Addition of Perceived Air Pollution Source Strength and Influence of Air Temperature on Olfactory Sensation / p47 (0028.jp2)
  18. 3-1 Introduction / p49 (0029.jp2)
  19. 3-2 Addition of olfs / p53 (0031.jp2)
  20. 3-3 Influence of air temperature on olfactory sensation / p67 (0038.jp2)
  21. 3-4 Conclusions / p85 (0047.jp2)
  22. Chapter4 / p87 (0048.jp2)
  23. Distribution of Perceived Air Pollution Measured by Trained Panel / p87 (0048.jp2)
  24. 4-1 Introduction / p89 (0049.jp2)
  25. 4-2 Trained panel / p91 (0050.jp2)
  26. 4-2 Experiment1(Distribution of perceived air pollution measured by trained panel) / p98 (0054.jp2)
  27. 4-3 Experiment2(Removal efficiency of perceived air pollutants) / p114 (0062.jp2)
  28. 4-4 Conclusions / p133 (0071.jp2)
  29. Chapter5 / p135 (0072.jp2)
  30. Method for Evaluating Removal Efficiency against Perceived Air Pollutants by Air Cleaners / p135 (0072.jp2)
  31. 5-1 Introduction / p137 (0073.jp2)
  32. 5-2 Experimental method / p138 (0074.jp2)
  33. 5-3 Results / p145 (0077.jp2)
  34. 5-4 Discussion / p157 (0083.jp2)
  35. 5-5 Conclusions / p158 (0084.jp2)
  36. Chapter6 / p161 (0085.jp2)
  37. Perceived Air Pollution Emitted from Building Materials and Olfactory Adaptation / p161 (0085.jp2)
  38. 6-1 Introduction / p163 (0086.jp2)
  39. 6-2 Comparison between olf values measured in small jar and that in big jar / p166 (0088.jp2)
  40. 6-3 Effect of surface air velocity on surface emission rate of perceived air pollutants / p177 (0093.jp2)
  41. 6-4 Olfactory adaptation of the subjects exposed to the space polluted by rubber-mat / p193 (0101.jp2)
  42. 6-5 Conclusions / p205 (0107.jp2)
  43. Conclusive Summary / p207 (0108.jp2)
  44. References / p217 (0113.jp2)
  45. Nomenclature / p227 (0118.jp2)