Fundamental study on base-isolation systems for electric power facilities 電力施設に使用する免震システムの基礎的研究
Access this Article
Search this Article
Author
Bibliographic Information
- Title
-
Fundamental study on base-isolation systems for electric power facilities
- Other Title
-
電力施設に使用する免震システムの基礎的研究
- Author
-
鈴木, 英世
- Author(Another name)
-
スズキ, ヒデヨ
- University
-
東北大学
- Types of degree
-
博士 (工学)
- Grant ID
-
乙第5920号
- Degree year
-
1992-12-09
Note and Description
博士論文
Table of Contents
- CONTENTS / p5 (0006.jp2)
- <Acknowledgements> / p3 (0004.jp2)
- <Abstract> / p9 (0010.jp2)
- Chapter ONE:INTRODUCTION / p1 (0013.jp2)
- 1.1 General / p1 (0013.jp2)
- 1.2 Objectives / p4 (0016.jp2)
- 1.3 Case Studies on Damage of Power Facilities Caused by Past Major Earthquakes / p5 (0017.jp2)
- 1.4 Past Technology of Base Isolated structures for General Purposes / p15 (0027.jp2)
- References / p29 (0041.jp2)
- Chapter TWO:BASIC CONSIDERATION OF BASE-ISOLATION SYSTEMS FROM A VIBRATION THEORY POINT OF VIEW / p34 (0046.jp2)
- 2.1 General / p34 (0046.jp2)
- 2.2 Responses of Base-isolation System to Harmonic Motion Input / p36 (0048.jp2)
- 2.3 Responses of Base-isolation System to Random Motion Input / p40 (0052.jp2)
- 2.4 Comparison of Response Waves of Various Base-isolation Systems --Elasto-plastic, Frictional and Viscous Systems-- / p48 (0060.jp2)
- 2.5 Summary / p51 (0063.jp2)
- References / p65 (0077.jp2)
- Chapter THREE:DEVELOPMENT OF NEW BASE-ISOLATION DEVICES / p67 (0079.jp2)
- 3.1 General / p67 (0079.jp2)
- 3.2 Development of New Base-isolation Device Using Frictional System / p69 (0081.jp2)
- 3.3 Development of High-Damping Laminated Rubber Device / p70 (0082.jp2)
- 3.4 Development of New Viscous Damper / p74 (0086.jp2)
- 3.5 Scale Model Tests on Shaking Table / p77 (0089.jp2)
- 3.6 Analytical Simulation of Scale Model Tests--Considering Non-linearity of Restoring Force-- / p81 (0093.jp2)
- 3.7 Analysis by Means of Equivalent Linear Method for Elasto-plastic Restoring Force / p84 (0096.jp2)
- 3.8 Summary / p87 (0099.jp2)
- References / p119 (0131.jp2)
- Chapter FOUR:EARTHQUAKE OBSERVATION OF A TRANSFORMER WITH BASE-ISOLATION DEVICES OF FRICTIONAL SYSTEM / p121 (0133.jp2)
- 4.1 General / p121 (0133.jp2)
- 4.2 Outline of Observation System / p121 (0133.jp2)
- 4.3 Results of Observation / p122 (0134.jp2)
- 4.4 Numerical Simulation by Sway and Rocking Model / p123 (0135.jp2)
- 4.5 Summary / p125 (0137.jp2)
- Reference / p134 (0146.jp2)
- Chapter FIVE:A DESIGN OF APPLICATION FOR AN ULTRA HIGH VOLTAGE TRANSFORMERS / p135 (0147.jp2)
- 5.1 General / p135 (0147.jp2)
- 5.2 Assumed Design Condition / p136 (0148.jp2)
- 5.3 Base-isolation Design for Transformer / p136 (0148.jp2)
- 5.4 Dynamic Analyses / p138 (0150.jp2)
- 5.5 Summary / p140 (0152.jp2)
- References / p159 (0171.jp2)
- Chapter SIX:CONCLUSIONS / p160 (0172.jp2)
- Notation / p165 (0177.jp2)
- List of Figures and Tables / p169 (0181.jp2)
- Related Publications by the Author / p176 (0188.jp2)
- APPENDICES / (0190.jp2)
- Appendix I.Analysis Tool for Non-linear Calculation / p179 (0191.jp2)
- Appendix II.Formulation for Stationary Response of Elasto-plastic System(Superstructure of One Mass Model with Spring and Damper) / p187 (0199.jp2)
- Appendix III.Formulation for Stationary Response of Elasto-plastic System( Superstructure of One Mass Model without Spring and Damper) / p194 (0206.jp2)