Safety and Efficacy of Radiofrequency Ablation with Artificial Ascites for Hepatocellular Carcinoma

この論文をさがす

抄録

The artificial ascites technique is often used during radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC) treatment because it prevents visceral damage and improves visualization by minimizing interference of the lungs and mesentery. This study determined the efficacy and safety of RFA using the artificial ascites technique in HCC patients. We examined 188 HCC patients who were treated by RFA and fulfilled the Milan criteria. Treatment outcomes (complete ablation rate, local recurrence rate, complication rate, liver function including total bilirubin level, alanine aminotransferase level, albumin level, and prothrombin time) were compared among patients divided into 3 groups based on the volume of artificial ascites injected:GroupⅠ (n=86), no artificial ascites injected;GroupⅡ (n=35), <1,000ml artificial ascites injected;and Group Ⅲ (n=67), >1,000ml artificial ascites injected. No significant difference was observed in complete ablation or local recurrence rates among the 3 groups, or in the extent of liver function damage after RFA. Artificial ascites disappeared within 7 days; additional diuretics were needed only in 5 (all from Group Ⅲ) of 102 patients. No serious complications such as intestinal perforation or intraperitoneal bleeding were observed. Thus, we found that artificial ascites injection during RFA is effective and safe, and can be used to prevent major procedural complications.

収録刊行物

  • Acta Medica Okayama

    Acta Medica Okayama 66 (3), 279-284, 2012-06

    Okayama University Medical School

詳細情報 詳細情報について

問題の指摘