The Periodic Operation of a Semiconductor Gas Sensor and Its Application to the Discrimination of Inflammable Gases

書誌事項

タイトル別名
  • Periodic Operation of a Semiconductor G

この論文をさがす

抄録

A new operation method of a semiconductor gas sensor is proposed to improve the gas selectivity and temperature-humidity characteristics of the sensor. In the method the heater voltage of the sensor is changed periodically, named periodic operation, for a certain time interval after inflammable gases were introduced. The method is examined in discriminating five kinds of inflammable gases with a three-layered BP neural network, and high discrimination rate (average 98%) is achieved.

収録刊行物

参考文献 (7)*注記