書誌事項
- タイトル別名
-
- PERMEABILITY AND LUGEON VALUES OF DAM FOUNDATIONS
- ダム キソ ノ トウスイセイ ト ルジオンチ
この論文をさがす
抄録
In surveying the permeability of dam foundations, Lugeon water test is usually adopted and the permeability is evaluated by Lugeon value (Lu). The curve between pressure and rate of water injection (p-q curve) is drawn by using the test results and Lugeon value is obtained from the slope of straight line part of p-q curve. However, quite a few p-q curves which have various shapes except the straight line, are obtained when Lugeon water tests are performed at fields. Therefore, in order to interpret the results of Lugeon water tests accurately the authors performs the following things: (1) p-q curves obtained from Lugeon water tests are classified into several categories, (2) causes of several p-q curves classified in (1) are summarized, (3) the methods to determine the accurate Lugeon value from each p-q curve are illustrated.
収録刊行物
-
- 土木学会論文集
-
土木学会論文集 1989 (412), 51-60, 1989-12-20
公益社団法人 土木学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001205308967168
-
- NII論文ID
- 130003799796
- 10003616946
-
- NII書誌ID
- AN10014020
-
- ISSN
- 18827187
- 02897806
-
- NDL書誌ID
- 3650673
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可