Depth-Dose Distributions of High-Energy Carbon, Oxygen and Neon Beams in Water

この論文にアクセスする

この論文をさがす

著者

    • KANAI Tatsuaki
    • Division of Accelerator Physics and Engineering, National Institute of Radiological Sciences

抄録

As part of the physics program of the heavy-ion therapy project at GSI (Germany), we have developed a one-dimensional model and a computer code for calculating the depth-dose, dose average LET, fluence and energy disributions for protons or light ions in medium. Measurements of the depth-dose disributions for beams of <SUP>12</SUP>C (195,270 and 330 MeV/u),<SUP>18</SUP>O (200,300 and 400MeV/u) and <SUP>20</SUP>Ne (670MeV/u) were performed at the heavy-ion synchrotron SIS using water as a tissue-equivalent target. At the RIKEN ring cyclotron depth-dose and dose average LET disributions were measured for <SUP>12</SUP>C and <SUP>20</SUP>Ne at 135 MeV/u. The calculated distributions were compared to the measured ones and good agreement was obtained for all systems studied.

収録刊行物

  • 放射線医学物理

    放射線医学物理 18(1), 1-21, 1998-03-31

    Japan Society of Medical Physics

参考文献:  58件中 1-58件 を表示

被引用文献:  4件中 1-4件 を表示

各種コード

  • NII論文ID(NAID)
    10003724212
  • NII書誌ID(NCID)
    AA11137895
  • 本文言語コード
    ENG
  • 資料種別
    ART
  • ISSN
    09188010
  • データ提供元
    CJP書誌  CJP引用  J-STAGE 