書誌事項
- タイトル別名
-
- Practical Analysis Method of Induced Damper Bar Currents of Salient-Pole Synchronous Machines due to Stator Slot Ripple
- トツキョクガタ ドウキキ ダンパ マキセン ニ オケル スロットリプル デンリュウ ノ カンイ カイセキ
この論文をさがす
抄録
This paper describes a simple analysis method of induced damper bar currents of salient-pole synchronous machines due to stator slot ripple and the calculated results of the damper bar currents of a 250kW 4-poles machine.<br>The proposed method is based on a gap permeance model of salient-pole machines considering the peripheral variation of the gap permeance and the field mmf distribution. The damper bar currents are calculated by considering the peripheral positions of the damper bars. The validity of the proposed analysis method is shown by the good agreement with the measured currents and analyzed currents by the two dimensional electromagnetic field analysis, of the 250kW 4-poles machine. Therefore it is useful for practical damper bar designers, because of its simpleness to be used and its accuracy of the analyzed currents.
収録刊行物
-
- 電気学会論文誌D(産業応用部門誌)
-
電気学会論文誌D(産業応用部門誌) 119 (7), 1004-1009, 1999
一般社団法人 電気学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204657478528
-
- NII論文ID
- 10004296936
-
- NII書誌ID
- AN10012320
-
- ISSN
- 13488163
- 09136339
-
- NDL書誌ID
- 4780619
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可