LNGコンパインド火力発電所排ガス条件下の炭酸ガス分離・回収への化学吸収法の適応性

書誌事項

タイトル別名
  • Applicability of Chemical Absorption Process to Carbon Dioxide Removal and Recovery under Effluent Gas Conditions of LNG Combined Cycle Power Plant.
  • LNG コンバインド カリョク ハツデンショ ハイガス ジョウケン カ ノ タンサンガス ブンリ カイシュウ エ ノ カガク キュウシュウホウ ノ テキオウセイ

この論文をさがす

抄録

Carbon dioxide removal was carried out on LNG combined cycle Power station flue gas up to about 3% CO2 concentration, using a pilot-scale absorber of about 23 m height at an exhaust gas flow rate of 770m3/h. Test results show a chemical absorption process using KS-1 solution, which is a hindered type alkanolamine, exhibits good applicability to the present condition. The degree of CO2 removal is higher than 90% in the range of CO2 concentration of 3.4% to 10.3% by the selection of the proper steam consumption. The thermal energy increases as the CO2 concentration decreases. In the case of KS-1 solution, the thermal energy is as low as 3.5×103kJ/kg CO2, even at a CO2 concentration of 3.4%.