歯科用CAD/CAM「セレック2」システム・クラウンの支台形態と適合性

  • 風間 龍之輔
    新潟大学大学院医歯学総合研究科口腔生命科学専攻口腔健康科学講座う蝕学分野
  • 福島 正義
    新潟大学大学院医歯学総合研究科口腔生命科学専攻口腔健康科学講座う蝕学分野
  • 岩久 正明
    新潟大学大学院医歯学総合研究科口腔生命科学専攻口腔健康科学講座う蝕学分野

書誌事項

タイトル別名
  • Effect of Tooth Preparation on Adaptation of Dental CAD/CAM "Cerec 2" Crowns.

この論文をさがす

抄録

The purpose of this study was to examine the effect of tooth preparation on marginal and internal fit of all ceramic crowns fabricated by dental CAD/CAM “CEREC 2” system. There were two test conditions for the margins as well as for the occlusal surfaces. Margin types were: a) horizontal and b) inclined. Occlusal surfaces were: a) flat and b) V shape. “Spacer” mode was set at 30μEm. Five specimens of each test condition type were prepared on the extracted human molars. All of the tested crowns were seated on the tooth preparations with adhesive resin cement. The specimens were cut mesiodistally at the center of tooth crown. The thickness of the adhesive resin cement layer on seven measured points on the cut surface was measured using a measuring microscope.<BR>As a result, models with horizontal margin and flat occlusal surface presented the best conditions for crown fitting.

収録刊行物

  • 接着歯学

    接着歯学 19 (3), 214-219, 2001

    日本接着歯学会

被引用文献 (1)*注記

もっと見る

参考文献 (9)*注記

もっと見る

詳細情報

問題の指摘