ニッケルチタンファイル使用時に発生する各種アクシデントの比較研究  [in Japanese] Comparison study of accidents with Ni-Ti files  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

<p><b>Abstract : </b>Recently, Ni-Ti files are used in endodontic therapy, and many investigators have reported that characterization of Ni-Ti files. However, many clinicians are perplexed to select proper various newly Ni-Ti files. In this study, we examined the accidents when using Ni-Ti files : Quantec and ProFile, on root canal enlargement. The perforation of canal wall occurred using#9 Quantec, 2 canals per 20 root canals, however, no perforation was observed using ProFile. The broken instruments were observed 2 cases on using Quantec and 1 case on using ProFile, respectively. The dentin muds at apical area were produced in using both Ni-Ti files, 3 canals in Quantec and 1 canal in ProFile, respectively. When using Ni-Ti files, we have to know the characterization and prevention of those accidents.</p>

Journal

  • The Journal of Japan Endodontic Association

    The Journal of Japan Endodontic Association 21(2), 95-100, 2000-12-25

    Japan Endodontic Association

References:  15

Cited by:  6

Codes

  • NII Article ID (NAID)
    10008152805
  • NII NACSIS-CAT ID (NCID)
    AN10443184
  • Text Lang
    JPN
  • Article Type
    Journal Article
  • ISSN
    13406248
  • Data Source
    CJP  CJPref  J-STAGE 
Page Top