顎口腔機能統合検査装置の応用によるバーチャル咬合器の開発  [in Japanese] Manufacture of a Virtual Articulator by Application of the Scientific Research lnstrument for Stomatognathic Functions  [in Japanese]

Access this Article

Search this Article

Author(s)

    • 竹市 卓郎 TAKEICHI Takurou
    • 愛知学院大学歯学部歯科補綴学第三講座 Department of Fixed Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 阿部 俊之 ABE Toshiyuki
    • 愛知学院大学歯学部歯科補綴学第三講座 Department of Fixed Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 鍋田 伸郎 NABETA Nobuo
    • 愛知学院大学歯学部歯科補綴学第三講座 Department of Fixed Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 墨 温子 SUMI Atsuko
    • 愛知学院大学歯学部歯科補綴学第三講座 Department of Fixed Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 伊藤 裕 ITO Yutaka
    • 愛知学院大学歯学部歯科補綴学第三講座 Department of Fixed Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 加藤 栄蔵 KATO Eizo
    • 愛知学院大学歯学部歯科補綴学第二講座 The Second Department of Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 市原 加文枝 ICHIHARA Kayoe
    • 愛知学院大学歯学部歯科補綴学第二講座 The Second Department of Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 川口 豊造 KAWAGUCHI Toyozo
    • 愛知学院大学歯学部歯科補綴学第二講座 The Second Department of Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 林 達秀 HAYASHI Tatsuhide
    • 愛知学院大学歯学部歯科補綴学第二講座 The Second Department of Prosthodontics, School of Dentistry,Aichi-Gakuin University
    • 八木橋 信 YAGIHASHI Makoto
    • 名古屋工業大学工学部機械工学科 Department of Mechanical Engineering, Faculty of Engineering, Nagoya lnstitute of Technology
    • 藤本 英雄 FUJIMOTO Hideo
    • 名古屋工業大学工学部機械工学科 Department of Mechanical Engineering, Faculty of Engineering, Nagoya lnstitute of Technology

Abstract

A virtual articulator was constructed on a computer monitor screen, from a stone dental model that was constructed by a 3 dimensional form measuring device and the measuring results of a submaxillary 6-degree-of-freedom movement. And a tracing of mandibular movements of a patient was reproduced. The relationship between mandibular movements and the occlusal pattern was visually constructed. Simulation of various occlusal conditions became possible by the virtual articulator at this time.

Journal

  • Nihon Hotetsu Shika Gakkai Zasshi

    Nihon Hotetsu Shika Gakkai Zasshi 44(6), 739-745, 2000-12-10