バルビツール酸誘導体を用いた歯科用常温重合レジンにおける触媒の影響

書誌事項

タイトル別名
  • Development of New Initiator of Polymerization for Self-Curing Resin with Barbituric Acid Derivatives.

この論文をさがす

抄録

The three barbituric acid derivatives were found to be effective as polymerization initiators instead of using Benzoylperoxide-tertAmine. Of the three derivatives, 1-Cyclohexyl-5-ethyl barbituric acid (CEBA) was the most effective for the HAZE value. The setting time was the fastest at 1.0 phr of CEBA. The optimum content of Acetylacetone copper (ACu) was 10ppm. The higher the content of ACu, the faster the setting time and the more bluish the color of the cured specimens. The lower the content of ACu, the slower the setting time. Dilauryl dimethyl ammonium chloride (LMAC) was more effective for the setting time, but the setting time was not significantly different due to the content of LMAC as determined by ANOVA. The residual monomer content of the cured self-curing resin using new initiator (Ba-Cl-Cu) in acetone and water was higher than for the conventional resin (BP0-tertAmine). To reduce the residual monomer, the cured specimen should be immersed in water for at least 1 hour prior to oral insertion.

収録刊行物

被引用文献 (8)*注記

もっと見る

参考文献 (15)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ