臼歯部中間欠損症例における可撤性ブリッジの咬合力配分 : 第1報支台歯および支持組織における二次元有限要素法による実験的検討  [in Japanese] Stress Distribution in Tooth Supported Removable Bridge with Long Saddle : Part 1. Stress Analysis at Abutment Teeth and Alveolar Bone by 2-Dimensional Finite Element Method  [in Japanese]

Access this Article

Search this Article

Author(s)

    • 井上 義久 INOUE Yoshihisa
    • 松本歯科大学歯科補綴学第1講座 Department of Removable Prosthodontics, Matsumoto Dental University School of Dentistry
    • 黒岩 昭弘 KUROIWA Akihiro
    • 松本歯科大学歯科補綴学第1講座 Department of Removable Prosthodontics, Matsumoto Dental University School of Dentistry
    • 緒方 彰 OGATA Akira
    • 松本歯科大学歯科補綴学第1講座 Department of Removable Prosthodontics, Matsumoto Dental University School of Dentistry
    • 鈴木 章 SUZUKI Akira
    • 松本歯科大学歯科補綴学第1講座 Department of Removable Prosthodontics, Matsumoto Dental University School of Dentistry
    • 大野 孝文 OHNO Takafumi
    • 松本歯科大学歯科補綴学第1講座 Department of Removable Prosthodontics, Matsumoto Dental University School of Dentistry

Abstract

The occlusal stress distribution and displacement of model in a supported tooth were examined.<BR>The effects of presence or absence of the bound saddle on the residual ridge and the rigidity of the removable bridge were evaluated by 2-dimensional finite element method.<BR>The results were as follows:<BR>1. Stress distribution on the abutment teeth under loading was more dispersed in the plate type removable bridge than in the non-plate type removable bridge. This finding was observed more markedly in canine abutment than in that of the second molar.<BR>2. Displacement of the node of the removable bridge under loading was decreased in the plate type removable bridge than in the nonplated type removable bridge.<BR>3. Irrespective of the presence or absence of the plate, the stress distribution in the abutment teeth under loading was more dispersed in the removable bridge made of metal with high Young's modulus than in the bridge with low Young's modulus.<BR>4. Irrespective of the presence or absence of the plate, displacement of the node of the removable bridge under loading was more decreased using the removable bridge made of metal with high Young's modulus than in the bridge with low Young's modulus.

Journal

  • Nihon Hotetsu Shika Gakkai Zasshi

    Nihon Hotetsu Shika Gakkai Zasshi 42(5), 823-831, 1998-10-10

    Japan Prosthodontic Society

References:  28

Cited by:  1