低刺激性直接リライニング材で裏装した加熱重合型床用レジンの比例限における曲げ強さ  [in Japanese] Transverse Strength at the Proportional Limit of a Heat-Cured Denture Base Resin Relined with Low Stimulative Direct Denture Reline Materials  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

This study was conducted to investigate the transverse strength at the proportional limit of a heat-cured denture base resin relined with low stimulative direct denture reline materials. The relined specimens with three low stimulative and a conventional self-cured direct denture reline materials were tested with a three-point loading test after 1 day of water immersion. Direction of load on the specimens also was tested. As a result, all relined specimens had significantly lower transverse strength than bulk of a heat-cured denture base material. The transverse strength of specimens relined with low stimulative direct denture reline materials was significantly low as compared with specimens relined with a conventional self-cured type direct denture reline material. There was no significant difference among three low stimulative direct denture reline materials. The direction of load on the specimens did not have an effect on the transverse strength at the proportional limit.

Journal

  • Nihon Hotetsu Shika Gakkai Zasshi

    Nihon Hotetsu Shika Gakkai Zasshi 43(5), 867-870, 1999-10-10

    Japan Prosthodontic Society

References:  14

Cited by:  3

Codes

  • NII Article ID (NAID)
    10008174567
  • NII NACSIS-CAT ID (NCID)
    AN00197911
  • Text Lang
    JPN
  • Article Type
    Journal Article
  • ISSN
    03895386
  • Data Source
    CJP  CJPref  J-STAGE 
Page Top