4‐META/MMA‐TBBレジンの操作可能時間を延長させるための一考案 第2報・スーパーボンドステーションの改良について

書誌事項

タイトル別名
  • Prolongation of Working-time for 4-META/MMA-TBB Resin. Part2. Modification of Super Bond Station.
  • Part2. Modification of Super Bond Station
  • 第2報・スーパーボンドステーションの改良について

この論文をさがす

抄録

4-META/MMA-TBB Resin (Super Bond C & B) has many advantages and has been used in dental treatments. However the complicated using procedure has many problems. Especially in moist and high temperature condition, the increase of viscosity is so faster that the working-time is shorter. In order to solve this problem, to cool the dappen dish was commonly used. But it was difficult to adapt this material for cementing many abutments even if the dappen dish was cooled. To solve this problem easily, we developed “Super Bond Station” for keeping low temperature and anti-dwelling on the surface of the cooled dappen dish, and have already reported. We modified the Super Bond Station in respect of easy operation with the effect of maintaining the cooled air. We estimate the modified Super Bond Station and confirmed the easy operation, the reduction of humidity and the effect of maintaining the cooled air. In this study, we reported the availability of the modified Super Bond Station.

収録刊行物

  • 接着歯学

    接着歯学 15 (2), 134-140, 1997

    日本接着歯学会

被引用文献 (4)*注記

もっと見る

参考文献 (6)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘