電離指数計算による標準球ギャップの火花電圧変動に関する検討 : 電界利用率の変化と火花電圧変化との関連性について  [in Japanese] Study on the change of sparkover voltages of the standard sphere gaps by calculation of ionization index : Relation between the change of field utilization factor and the one of sparkover voltage  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

The field utilization factor η (the mean electric field/the maximum electric field) of the standard sphere gaps was calculated by the charge simulation method, taking into account the ground plane and shanks. Sparkover voltages were also calculated by integration of ionization index, except the sparkover for positive impulse.<br> η and the sparkover voltage may change by the length and the diameter of shanks in the range permitted by the IEC standard 60052. Generally, the rate of the change of sparkover voltage is not larger than the one of η, because the sparkover voltage is averaged by integration of ionization index on the center axis between the sphere electrodes. In the range where the gap length is near the sphere radius, the change rate of η and the sparkover voltage is almost same.<br> The reason is that the streamer criterion is satisfied near the crest point of the upper sphere electrode.

Journal

  • IEEJ Transactions on Power and Energy

    IEEJ Transactions on Power and Energy 122(5), 622-628, 2002-05-01

    The Institute of Electrical Engineers of Japan

References:  12

Codes

  • NII Article ID (NAID)
    10008217017
  • NII NACSIS-CAT ID (NCID)
    AN10136334
  • Text Lang
    JPN
  • Article Type
    ART
  • ISSN
    03854213
  • NDL Article ID
    6152885
  • NDL Source Classification
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL Call No.
    Z16-794
  • Data Source
    CJP  NDL  J-STAGE 
Page Top