血圧測定用テレメトリー送信機埋め込み手術のラットおよびウサギにおける体重,血圧および心拍数に及ぼす影響とその回復性  [in Japanese] Effects of implantation of telemetry transmitter and their recoveries on body weight, blood pressure and heart rate in rats and rabbits  [in Japanese]

Access this Article

Search this Article

Author(s)

    • 佐藤 恵一朗 SATO Keiichiro
    • 武田薬品工業(株)薬剤安全性研究所第1部 Department I, Drug Safety Research Laboratories, Takeda Chemical Industries, Ltd.
    • 茶谷 文雄 CHATANI Fumio
    • 武田薬品工業(株)薬剤安全性研究所第1部 Department I, Drug Safety Research Laboratories, Takeda Chemical Industries, Ltd.
    • 佐藤 秀蔵 SATO Shuzo
    • 武田薬品工業(株)薬剤安全性研究所第1部 Department I, Drug Safety Research Laboratories, Takeda Chemical Industries, Ltd.

Abstract

本実験において我々は4系統のラット(SHR, WKY, Wistar, F344)と1品種のウサギ(JW)を用いて,血圧測定用テレメトリー送信機埋め込み手術後2あるいは3週間にわたって体重,平均血圧および心拍数を測定し,それらの測定値に及ぼす手術の影響と回復性を調べた。<BR>WistarおよびF344の腹腔内に送信機を埋め込んだ場合,いずれも術後2~3日までは体重が減少したが,その後回復し,術後3週目には無処置対照群と同等になった。Wistarの腹腔内あるいは背部皮下に送信機を埋め込み,術後の体重変化を比較した結果,背部皮下に送信機を埋め込んだ場合の方が腹腔内埋め込みに比べて手術直後の体重減少が少なく,回復も早かった。また,SHR, WKYおよびJWにおけるテレメトリー送信機埋め込み手術2週後の体重は,手術時の体重以上あるいはそれとほぼ同等の数値を示し,これらの動物においても体重の回復性が確認された。<BR>ラットでは腹腔内,ウサギでは側腹部皮下に送信機を埋め込んだ場合,いずれも手術の翌日には平均血圧および心拍数の高値がみられたが,術後1週以降は明暗期平均値が安定した。また,術後1週間における平均血圧および心拍数の日内変動はラットおよびウサギのいずれにおいても乱れていたが,術後2週間目にはWKYの平均血圧を除くすべての項目で暗期に高値を示す夜行性動物特有の日内変動を明確に確認することができた。<BR>したがって,テレメトリー送信機埋め込み手術の後,体重の点ではラットで3週間以上,ウサギで2週間以上,血圧および心拍数の点ではラット,ウサギともに,1週間以上の術後回復期間を設定することにより,実験に供することが可能であると結論する。

A new telemetric system for arterial blood pressure has recently become popular in experimental studies. In this study, body weight (BW), mean blood pressure (MBP) and heart rate (HR) were measured for 2 or 3 weeks after implantation of a transmitter in 4 strains of rats (F344, Wistar, SHR and WKY) and 1 breed of rabbit (JW) to evaluate the effects of the implantation procedure on their parameters and to confirm their reversibilities.<BR>BW of Wistar and F344 were decreased for 3 days after implantation in each strain, but they began to increase again thereafter and there were no statistically significant difference from each control 3 weeks after implantation. The BW of Wistar rats more rapidly recovered after subcutaneous implantation than after intraperitoneal implantation. The BW of SHR, WKY and JW 2 weeks after implantation of a transmitter recovered to not less than those beforeimplantation.<BR>In SHR, WKY and Wistarrats, basal MBP and HR were noticeobly high just after intraperitoneal implantation, but these values became lower and stable about 1 week after the implantation. The circadian rhythms of MBP and HR were obviously disrupted for the first week, but returned to the nocturnal pattern in the second week except for MBP in WKY. In JW, MBP and HR were tended to be high for 6 and 2 days after implantation, respectively, but became stable thereafter. The circadian rhythms of MBP and HR in JW were disturbed for a few days, but then returned to the nocturnal patterns, as was the case in rats.<BR>We concluded that the recovery period after intraperitoneal (rats) or subcutaneous (rabbits) implantation of transmitter should be 2 or 3 weeks in view of the BW and 1 week in view of basal values and circadian rhythms in MBP and HR.

Journal

  • Advances in Animal Cardiology

    Advances in Animal Cardiology 28(1), 1-10, 1995-06

    Japanese Society of Veterinary Cardiology

References:  25

Cited by:  1

Codes

  • NII Article ID (NAID)
    10008286723
  • NII NACSIS-CAT ID (NCID)
    AN10192925
  • Text Lang
    JPN
  • Article Type
    Journal Article
  • ISSN
    09106537
  • Data Source
    CJP  CJPref  J-STAGE  JASI 
Page Top