誘導電動機駆動用平滑回路なし変換回路のPWM整流部における零電流スイッチング法  [in Japanese] A Zero Current Switching Strategy of PWM Rectifier of Converter without DC Link Components for Induction Motor Drives  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

A converter without DC Link components needs snubber circuits, in order to assure the path of the load current during the dead-time period of the PWM rectifier section. In the snubber circuits, losses have been dissipated every time the switches of the rectifier section are turned on and turned off. During the zero voltage vector period of the inverter section, the load current does not flow in the PWM rectifier section. So if each switching operations of the PWM rectifier section are done in the zero voltage vector period, it is not necessary to assure the path of the load current. Therefore, snubber circuits are not necessary in the PWM rectifier section. In this paper, we describe a zero current switching strategy of the PWM rectifier section during zero voltage vector periods of the inverter section. The proposed strategy is verified by computer simulation and experimental test on an induction motor drive.

Journal

  • IEEJ Transactions on Industry Applications

    IEEJ Transactions on Industry Applications 122(6), 624-632, 2002-06-01

    The Institute of Electrical Engineers of Japan

Cited by:  6

Codes

  • NII Article ID (NAID)
    10008509365
  • NII NACSIS-CAT ID (NCID)
    AN10012320
  • Text Lang
    JPN
  • Article Type
    Journal Article
  • ISSN
    09136339
  • NDL Article ID
    6175108
  • NDL Source Classification
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL Call No.
    Z16-1608
  • Data Source
    CJP  CJPref  NDL  J-STAGE 