Estimation of Thundercloud Direction by Horizontal Electric Field Meters
-
- Tantisattayakul Thanapol
- Toyama University
-
- Kitamura Iwao
- Toyama University
-
- Murai Tadakuni
- Toyama University
-
- Masugata Katsumi
- Toyama University
-
- Kami Koichiro
- Hokuriku Electric Power Co.
Bibliographic Information
- Other Title
-
- 雷雲の位置推定のための水平方向電界計の開発
- ライウン ノ イチ スイテイ ノ タメ ノ スイヘイ ホウコウ デンカイケイ ノ カイハツ
Search this article
Abstract
The horizontal electric field (Er) contains useful information for estimating position of thundercloud. Unfortunately, it is difficult to detect horizontal electric field (Er) due to electric field component on the earth surface is almost a vertical component. <br>We propose a new idea for horizontal electric field (Er) detection. We developed two types of horizontal electric field meter (HEFM), i. e., a fixed electrode-type and a rotating electrode-type, and evaluated their performance experimentally and found that they have sufficient sensitivity to Er to estimate the direction of thundercloud. In this paper, we present the result of performance evaluation and also present an electric field data measured by HEFMs as examples.
Journal
-
- IEEJ Transactions on Power and Energy
-
IEEJ Transactions on Power and Energy 124 (1), 121-126, 2004
The Institute of Electrical Engineers of Japan