Estimation of Kinetics Parameters for the Adsorption of Human Serum Albumin onto Hydroxyapatite-modified Silver Electrodes by Piezoelectric Quartz Crystal Impedance Analysis

DOI PDF Web Site Web Site Web Site View 1 Remaining Hide 58 References
  • TIAN Lu
    State Key Laboratory of Chemo/Biosensoring and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
  • WEI Wan-zhi
    State Key Laboratory of Chemo/Biosensoring and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
  • MAO You-an
    State Key Laboratory of Chemo/Biosensoring and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University

Search this article

Abstract

The adsorption of human serum albumin onto hydroxyapatite-modified silver electrodes has been in situ investigated by utilizing the piezoelectric quartz crystal impedance technique. The changes of equivalent circuit parameters were used to interpret the adsorption process. A kinetic model of two consecutive steps was derived to describe the process and compared with a first-order kinetic model by using residual analysis. The experimental data of frequency shift fitted to the model and kinetics parameters, k1, k2, ψ1, ψ2 and qr, were obtained. All fitted results were in reasonable agreement with the corresponding experimental results. Two adsorption constants (7.19 kJ mol-1 and 22.89 kJ mol-1) were calculated according to the Arrhenius formula.

Journal

  • Analytical Sciences

    Analytical Sciences 20 (4), 623-627, 2004

    The Japan Society for Analytical Chemistry

References(58)*help

See more

Details 詳細情報について

Report a problem

Back to top