直流機延命化のための電機子巻線再含浸基礎特性および遠赤外線照射の効果について Experimental Study of Re-impregnation Characteristics for Aged DC Machine and Effect of Application of Far Infrared Radiation to the process

この論文にアクセスする

この論文をさがす

著者

抄録

Recently hundreds of large dc machines manufactured for steel rolling mills at the high growing period are on the verge of replacement due to insulation deterioration of their armature windings after more than thirty years of service operation. Insulation technologies for aged machine are different from those for new machine, including varnish impregnation technologies.<br>In this paper, experimental study of basic impregnation characteristics for aged dc machine to extend its life is described.<br>Experimental study of application of far infrared radiation for the process is also presented.

収録刊行物

  • 電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society

    電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society 124(7), 716-723, 2004-07-01

    一般社団法人 電気学会