Quantitative Analysis of 17 .BETA.-Estradiol in River Water by Fluorometric Enzyme Immunoassay Using Biotinylated Estradiol

DOI PDF Web Site Web Site Web Site View 1 Remaining Hide 42 References
  • MATSUMOTO Yuko
    Division of Material Science, Graduate School of Environmental Earth Science, Hokkaido University
  • KURAMITZ Hideki
    Department of Environmental Biology and Chemistry, Faculty of Science, Toyama University
  • ITOH Shinji
    Hokkaido College of Pharmacy
  • TANAKA Shunitz
    Division of Material Science, Graduate School of Environmental Earth Science, Hokkaido University

Bibliographic Information

Other Title
  • Quantitative Analysis of 17β-Estradiol in River Water by Fluorometric Enzyme Immunoassay Using Biotinylated Estradiol
  • Quantitative Analysis of 17 ベータ Estradiol in River Water by Fluorometric Enzyme Immunoassay Using Biotinylated Estradiol

Search this article

Abstract

A sensitive and simple immunoassay to determine 17β-estradiol (E2) in fresh water was developed. The method is based on a solid-phase avidin-biotin binding assay and solid phase extraction. The binding event of E2 to the antibody is detected indirectly by the competitive reaction between E2 and biotinylated estradiol (BE) as a tracer for the limited binding sites of antibodies immobilized onto the wall of a microtiter plate. Namely, E2 concentrations are determined from the strong interaction between BE and avidin conjugated with horseradish peroxidase (avidin-HRP). In order to achieve a sensitive measurement for the binding of BE to the antibody immobilized on the microtiter plate substrate, QuantaBlu™ fluorogenic peroxidase substrate (QFPS) was employed. The detection limit and the linear range of E2 determination were 27 pM and 27 - 7480 pM, respectively. The relative standard deviations (RSD) for the E2 assay were between 0.3 and 12.0% (n = 3). The cross-reactivities of several other estrogens in this assay system were also investigated. No serious influences from any cross-reaction caused by other estrogens tested in this experiment were observed. The determination of E2 in water samples from eight rivers and a marsh in Hokkaido was performed by the immunoassay combined with solid phase extraction. It was found that the concentration of E2 was in the range between 0.06 and 67 pM.

Journal

  • Analytical Sciences

    Analytical Sciences 21 (3), 219-224, 2005

    The Japan Society for Analytical Chemistry

References(42)*help

See more

Details 詳細情報について

Report a problem

Back to top