Performance of U-shaped Core Orthogonal Fluxgate Magnetometer

  • Goleman K.
    Department of Applied Science for Electronic and Materials, Interdisciplinary Graduate School of Engineering Sciences, Kyushu University
  • Sasada I.
    Department of Applied Science for Electronic and Materials, Interdisciplinary Graduate School of Engineering Sciences, Kyushu University

この論文をさがす

抄録

We proposed a new method for decreasing transformer effect from excitation current to sense coil in an orthogonal fluxgate operated in the fundamental mode. The point of this method is to use a U-shaped magnetic wire core on each branch of which two identical sense coils are wound and to arrange the two coils in counter series. As a result, induced voltage is reduced by a factor of 1/3 from that observed with a single wire core. The levels of the magnetic noise and drift are reduced substantially. For example, the noise level at 10 Hz decreased from 0.5 n T/√Hz to 0.08 n T/√Hz for small excitation current 4.1 m A with 5.8 m A dc bias. The driftof the sensors is confined within the range 0.5 n T for the U-shaped F G and 1 n T for the single core F G.

収録刊行物

被引用文献 (2)*注記

もっと見る

参考文献 (4)*注記

もっと見る

詳細情報 詳細情報について

  • CRID
    1390282680200180096
  • NII論文ID
    10015504536
  • NII書誌ID
    AA1158094X
  • DOI
    10.3379/tmjpn2001.5.101
  • ISSN
    18846726
    13467948
    http://id.crossref.org/issn/13467948
  • 本文言語コード
    en
  • データソース種別
    • JaLC
    • Crossref
    • CiNii Articles
  • 抄録ライセンスフラグ
    使用不可

問題の指摘