Evaluation of Bone Quality near Metallic Implants with and without Lotus-Type Pores for Optimal Biomaterial Design

  • Nakano Takayoshi
    Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University
  • Kan Tomoko
    Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University
  • Ishimoto Takuya
    Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University
  • Ohashi Yoshio
    Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University Osaka Dental University Hospital
  • Fujitani Wataru
    Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University
  • Umakoshi Yukichi
    Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University
  • Hattori Tomokazu
    Department of Materials Science and Engineering, Faculty of Engineering, Meijo University
  • Higuchi Yuichi
    Osaka Dental University Hospital
  • Tane Masakazu
    The Institute of Scientific and Industrial Research, Osaka University
  • Nakajima Hideo
    The Institute of Scientific and Industrial Research, Osaka University

この論文をさがす

抄録

The stress shielding effect often degrades the quality and quantity of bones near implants. Thus, the shape and structure of metallic biomaterials should be optimally designed. A dominant inorganic substance in bones is a biological apatite (BAp) nanocrystal, which basically crystallizes in an anisotropic hexagonal lattice. The BAp c-axis is parallel to elongated collagen fibers. Because the BAp orientation of bones is a possible parameter of bone quality near implants, we used a microbeam X-ray diffractometer system with a beam spot, which had a diameter of 50 or 100 μmφ, to evaluate the BAp orientation of bones.<BR>Two animal models were prepared: (1) a nail model (φ: 3.0 mm, SUS316L), which was used to understand the stress shielding effect in a rabbit tibial marrow cavity, and (2) a model of a lotus-type porous implant (φ: 3.4 mm, mean pore diameter: 170 μm, SUS304L), which was used to understand the effect of the unidirectional-elongated pore direction in an anisotropic bone tissue of a beagle mandible. The porous implants were implanted so that the pore direction was parallel or perpendicular to the mesiodistal axis of mandible.<BR>For the porous implant model, new bone formation strongly depended on the elongated pore direction and the time after implantation. For example, four weeks after implantation, new bone formed in pores of the implants, but the BAp orientation degree in the new bone was more similar to that in the original bone in the elongated pores parallel to the mesiodistal direction than that in the perpendicular pores. These differences in bone formation inside the parallel and perpendicular pores may be closely related to the anisotropy of original bone tissues such as the orientations of collagen fiber, BAp, and blood vessels. The orientation degree of BAp also changed in the nail model. The stress shielding effect decreased the orientation degree of the BAp c-axis in the tibia along the longitudinal axis.<BR>Thus, optimal design of metallic biomaterials such as implant shape, pore size, elongated pore direction, etc., should be based on the anisotropy of the bone microstructure.

収録刊行物

被引用文献 (16)*注記

もっと見る

参考文献 (31)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ