Study on Application of Cooling in Apartment-House

  • MAE Masayuki
    Department of Architecture, School of Engineering, The University of Tokyo
  • NABESHIMA Minako
    Graduate School of Engineering, Osaka City University
  • EMURA Kazuo
    Graduate School of Human Life Science, Osaka City University
  • NAGAI Tatsuo
    Graduate School of Human Life Science, Osaka City University
  • NIMIYA Hideyo
    Department of Environmental Design, Nagaoka Institute of Design
  • KAMATA Motoyasu
    Department of Architecture, School of Engineering, The University of Tokyo

Bibliographic Information

Other Title
  • 集合住宅における冷房の使用状況に関する研究
  • シュウゴウ ジュウタク ニ オケル レイボウ ノ シヨウ ジョウキョウ ニ カンスル ケンキュウ

Search this article

Abstract

To evaluate cooling-heat-load in apartment houses, it is important to assume the application of Air-Conditioning by inhabitants. We studied on usage of cooling in apartment houses in Tsukaguchi, Hyogo-pref. First, We found 5 standard patterns of cooling time-zone from questionnaire collected from all houses. Then, by analysis of energy consumption of cooling in 9 selected houses, we found strong relation between cooling-application and outdoor-air-temperature, and usually cooling is applied when outdoor air-temperature is over 24-27℃. Also there are two time zones on daily application, cooling-time-zone and no-cooling-time-zone. It might be useful to determine the condition of cooling application in simulating cooling-heat-load.

Journal

Citations (7)*help

See more

References(10)*help

See more

Details 詳細情報について

Report a problem