Analysis and display of nystagmus using ImageJ-Based on the material for the standard examination of equilibrium-

  • Ikeda Takuo
    Department of Otolaryngology, Tsudumigaura Handicapped Children's Hospital
  • Hashimoto Makoto
    Department of Otolaryngology, Yamaguchi University School of Medicine
  • Yamashita Hiroshi
    Department of Otolaryngology, Yamaguchi University School of Medicine

Bibliographic Information

Other Title
  • ImageJを用いた眼振解析とその表示―平衡機能検査法基準化のための資料に基づいて―
  • —Based on the material for the standard examination of equilibrium—
  • —平衡機能検査法基準化のための資料に基づいて—

Search this article

Abstract

We devised a new analysis technique to display the nystagmus as an arrow based on the material for the standard examination of equilibrium. Three-dimensional eye movement image analysis was performed automatically using the public domain software ImageJ and a personal computer. The direction, amplitude and frequency of nystagmus were calculated from the result of horizontal, vertical and torsional components. The amplitude and frequency were classified into three phases based on the material for the standard examination of equilibrium. Using this technique, it was possible to display properties of the nystagmus as an arrow in detail on the computer.