Effect of overglazed and polished surface finishes on the compressive fracture strength of machinable ceramic materials
-
- ASAI Tetsuya
- Division of Cariology, Operative Dentistry and Endodontics, Department of Oral Health Science, Niigata University Graduate School of Medical and Dental Sciences
-
- KAZAMA Ryunosuke
- Removable Partial Denture Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University
-
- FUKUSHIMA Masayoshi
- Department of Oral Health and Welfare, Faculty of Dentistry, Niigata University
-
- OKIJI Takashi
- Division of Cariology, Operative Dentistry and Endodontics, Department of Oral Health Science, Niigata University Graduate School of Medical and Dental Sciences
Access this Article
Search this Article
Author(s)
-
- ASAI Tetsuya
- Division of Cariology, Operative Dentistry and Endodontics, Department of Oral Health Science, Niigata University Graduate School of Medical and Dental Sciences
-
- KAZAMA Ryunosuke
- Removable Partial Denture Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University
-
- FUKUSHIMA Masayoshi
- Department of Oral Health and Welfare, Faculty of Dentistry, Niigata University
-
- OKIJI Takashi
- Division of Cariology, Operative Dentistry and Endodontics, Department of Oral Health Science, Niigata University Graduate School of Medical and Dental Sciences
Abstract
Controversy prevails over the effect of overglazing on the fracture strength of ceramic materials. Therefore, the effects of different surface finishes on the compressive fracture strength of machinable ceramic materials were investigated in this study. Plates prepared from four commercial brands of ceramic materials were either surface-polished or overglazed (<I>n</I>=10 per ceramic material for each surface finish), and bonded to flat surfaces of human dentin using a resin cement. Loads at failure were determined and statistically analyzed using two-way ANOVA and Bonferroni test. Although no statistical differences in load value were detected between polished and overglazed groups (<I>p</I>>0.05), the fracture load of Vita Mark II was significantly lower than those of ProCAD and IPS Empress CAD, whereas that of IPS e.max CAD was significantly higher than the latter two ceramic materials (<I>p</I><0.05). It was concluded that overglazed and polished surfaces produced similar compressive fracture strengths irrespective of the machinable ceramic material tested, and that fracture strength was material-dependent.
Journal
-
- Dental Materials Journal
-
Dental Materials Journal 29(6), 661-667, 2010-11-01
The Japanese Society for Dental Materials and Devices
References: 38
-
1
- Ceramic vs porcelain-fused-to-metal crowns : give your patients a choice
-
CHRISTENSEN GJ.
J Am Dent Assoc 125, 311-314, 1994
Cited by (1)
-
2
- Effect of surface finish and fatigue testing on the fracture strength of CAD-CAM and pressed-ceramic crowns
-
CHEN HY
J Prosthet Dent 82, 468-475, 1999
Cited by (1)
-
3
- Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns
-
BINDL A
Dent Mater 22, 29-36, 2006
Cited by (1)
-
4
- All-ceramic partial coverage restorations on natural molars. Masticatory fatigue loading and fracture resistance
-
STAPPERT CF
Am J Dent 20, 21-26, 2007
Cited by (1)
-
5
- Brittleness index of machinable dental materials and its relation to the marginal chipping factor
-
TSITROU EA
J Dent 35, 897-902, 2007
Cited by (1)
-
6
- Influence of surface characteristics of four silica-based machinable ceramics on flexural strength and bond strength of a dual-curing resin luting agent
-
YOSHIDA K
J Adhes Dent 9, 407-413, 2007
Cited by (1)
-
7
- Effect of surface finish on the flexural strength of feldspathic and aluminous dental ceramics
-
GIORDANO R
Int J Prosthodont 8, 311-319, 1995
Cited by (1)
-
8
- Influence of layer and stain firing on the fracture strength of heat-pressed ceramics
-
UCTASLI S
J Oral Rehabil 23, 170-174, 1996
Cited by (1)
-
9
- Effect of heat treatment on microcrack healing behavior of a machinable dental ceramic
-
DENRY IL
J Biomed Mater Res 48, 791-796, 1999
Cited by (1)
-
10
- The influence of surface roughness on porcelain strength
-
DE JAGER N
Dent Mater 16, 381-388, 2000
Cited by (1)
-
11
- Effect of ion exchange of glazed dental glass ceramics on strength parameters
-
FISCHER H
J Biomed Mater Res A 72, 175-179, 2004
Cited by (1)
-
12
- An evaluation of the effects of handpiece speed, abrasive characteristics, and polishing load on the flexural strength of polished ceramics
-
AHMAD R
J Prosthet Dent 94, 421-429, 2005
Cited by (1)
-
13
- Influence of surface roughness on mechanical strength of resin composite versus glass ceramic materials
-
LOHBAUER U
Dent Mater 24, 250-256, 2008
Cited by (1)
-
14
- Comparison of porcelain surface and flexural strength obtained by microwave and conventional oven glazing
-
PRASAD S
J Prosthet Dent 101, 20-28, 2009
Cited by (1)
-
15
- Influence of film thickness on joint bend strength of a ceramic/resin composite joint
-
MOLIN MK
Dent Mater 12, 245-249, 1996
Cited by (1)
-
16
- Effect of resin luting film thickness on fracture resistance of a ceramic cemented to dentin
-
PRAKKI A
J Prosthodont 16, 172-178, 2007
Cited by (1)
-
17
- Effect of ceramic surface treatment on the shear bond strengths of two resin luting agents to all-ceramic materials
-
SAYGILI G
J Oral Rehabil 30, 758-764, 2003
Cited by (1)
-
18
- Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns
-
ATTIA A
J Prosthet Dent 95, 117-123, 2006
Cited by (1)
-
19
- Compressive fracture resistance of porcelain laminates bonded to enamel or dentin with four adhesive systems
-
PIEMJAI M
J Prosthodont 16, 457-464, 2007
Cited by (1)
-
20
- Fracture frequency of all-ceramic crowns during dynamic loading in a chewing simulator using different loading and luting protocols
-
HEINTZE SD
Dent Mater 24, 1352-1361, 2008
Cited by (1)
-
21
- Surface roughness of opalescent porcelains after polishing
-
WARD MT
Oper Dent 20, 106-110, 1995
Cited by (1)
-
22
- Effects of six surface treatment methods on the surface roughness of a low-fusing and an ultra low-fusing feldspathic ceramic material
-
DALKIZ M
J Prosthodont 18, 217-222, 2009
Cited by (1)
-
23
- A review of the strength properties of dental ceramics
-
HONDRUM SO.
J Prosthet Dent 67, 859-865, 1992
Cited by (1)
-
24
- An overview of treatment considerations for esthetic restorations : a review of the literature
-
SADOWSKY SJ.
J Prosthet Dent 96, 433-442, 2006
Cited by (1)
-
25
- Fracture strength of all-ceramic crowns luted using two bonding methods
-
ATTIA A
J Prosthet Dent 91, 247-252, 2004
Cited by (1)
-
26
- Dental ceramics and the molar crown testing ground
-
THOMPSON VP
J Appl Oral Sci 12, 26-36, 2004
Cited by (1)
-
27
- Measurement of select physical and mechanical properties of 3 machinable ceramic materials
-
CHARLTON DG
Quintessence Int 39, 573-579, 2008
Cited by (1)
-
28
- Fracture load of CAD/CAM-generated slot-inlay FPDs
-
BINDL A
Int J Prosthodont 16, 653-660, 2003
Cited by (1)
-
29
- The effect of glaze on porcelain strength
-
FAIRHURST C. W.
Dent Mater 8, 203-207, 1992
DOI Cited by (2)
-
30
- Effects of Flaw Size and Auto-glaze Treatment on Porcelain Strength
-
GRIGGS J. A. , THOMPSON J. Y. , ANUSAVICE K. J.
J Dent Res 75(6), 1414-1417, 1996-06-01
References (14) Cited by (2)
-
31
- Effect of cement film thickness on the fracture resistance of a machinable glass-ceramic
-
SCHERRER SS
Dent Mater 10, 172-177, 1994
DOI Cited by (2)
-
32
- The effect of luting media on the fracture resistance of a flame sprayed all-ceramic crown
-
CASSON AM
J Dent 29, 539-544, 2001
DOI Cited by (2)
-
33
- Influence of cyclic loading and luting agents on the fracture load of two all-ceramic crown systems
-
ATTIA A
J Prosthet Dent 92, 551-556, 2004
DOI Cited by (2)
-
34
- Studies on the wear of porcelain, enamel, and gold
-
TAYLOR D. F.
J Prosthet Dent 25, 299-306, 1971
DOI Cited by (11)
-
35
- An evaluation of porcelain strength and the effect of surface treatment
-
BRACKETT SE.
J Prosthet Dent 61, 446-451, 1989
DOI Cited by (3)
-
36
- Effect of various treatment and glazing (coating) techniques on the roughness and wettability of ceramic dental restorative surfaces
-
AKSOY G
Colloids Surf B Biointerfaces 53, 254-259, 2006
Cited by (1)
-
37
- Dynamic fatigue of treated high-silica glass : explanation by crack tip blunting
-
KAZUYUKI H
J Am Ceram Soc 70, 377-382, 1987
Cited by (2)
-
38
- Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics
-
TINSCHERT J
J Dent 28, 529-535, 2000
DOI Cited by (9)