LABORATORY-BASED EVALUATION OF BREAKTHROUGH BACTERIAL CONTAMINATION DURING PREDEPOSIT-TYPE AUTOLOGOUS BLOOD TRANSFUSION PREPARATION
-
- Tanokuchi Yuko
- Blood Transfusion Units, University Hospital of the Ryukyus
-
- Higa Hatsuko
- Blood Transfusion Units, University Hospital of the Ryukyus
-
- Yamane Nobuhisa
- Blood Transfusion Units, University Hospital of the Ryukyus Department of Laboratory Medicine, Graduate School and Faculty of Medicine, University of the Ryukyus Clinical Laboratories, University Hospital of the Ryukyus
-
- Nakasone Isamu
- Clinical Laboratories, University Hospital of the Ryukyus
-
- T. Tokashiki Yoshino
- Clinical Laboratories, University Hospital of the Ryukyus
Bibliographic Information
- Other Title
-
- 貯血式自己血輸血製剤の採取に伴う細菌汚染の評価
Search this article
Abstract
Breakthrough bacterial contamination during blood collection is a potential risk in predeposit-type autologous blood transfusion. A total of 2,209 blood samples were collected from July 2005 to May 2009 for autologous blood transfusion at the University Hospital of the Ryukyus. The first 5 ml of blood samples was cultured in BACTEC Plus Aerobic/F blood culture bottles to detect bacterial contamination. Bacterial growth was monitored by an automated blood culture system, BACTEC 9120. Of 2,209 blood samples, 4 (0.18%) were positive, with two strains of Staphylococcus hominis, and one each of S.warneri and S.capitis. Bacterial concentrations in blood samples were determined using linear regression between the time (hour) to detect positive and colony-forming units (cfu)/ml of the respective isolates. It was demonstrated that three positive blood samples contained 0.06 to 5.3 cfu/ml while the other, positive for S.warnerii, was 1.4×104 cfu/ml. To evaluate the benefit of removing white blood cells, S.hominis isolate was spiked into an aseptic blood sample from which white blood cells were removed. This preparation revealed significant exponential bacterial growth after standing for 16 hours at room temperature. However, an aseptic blood sample containing a normal number of white blood cells did not show any significant bacterial growth within a 24-hour period. Microscopic examination confirmed that a number of white blood cells had phagocytosed the spiked staphylococcal cells. From these results, we concluded that the breakthrough bacterial contamination ratio was significantly low, but not negligible. Thus, care is necessary in the collection of blood, particularly in disinfection procedures. The benefits of removing white blood cells from the preparation for autologous blood transfusion is an issue that should be discussed further.<br>
Journal
-
- Japanese Journal of Transfusion and Cell Therapy
-
Japanese Journal of Transfusion and Cell Therapy 56 (3), 354-358, 2010
The Japan Society of Transfusion Medicine and Cell Therapy
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001205272471296
-
- NII Article ID
- 10027584345
- 130004542611
-
- NII Book ID
- AA12159645
-
- ISSN
- 18830625
- 18813011
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed